SOP for Oparation of centrifuge
1.0 OBJECTIVE
To provide a guideline for operation, cleaning and calibration procedure of NUVE Bench Top centrifuge machine.
2.0 SCOPE
This SOP is applicable for the operation, cleaning and calibration procedure of NUVE Bench Top centrifuge machine at Quality Control Department (Company Name).
3.0 RESPONSIBILITY
3.1 ...
SOP for Cleaning of Accessories Utensils used for Sampling
1.0 OBJECTIVE
To lay down the procedure for cleaning of accessories / utensils used for sampling of raw materials.
2.0 SCOPE
This SOP is applicable for the cleaning of the sampling accessories / utensils used for the sampling of raw materials under R-LAF in the warehouse.
3.0 RESPONSIBILITY
3.1 QC officer ...
SOP for Transfer of Materials, equipment & accessories
1.0 OBJECTIVE
To provide a general guideline for transferring materials, equipment, accessories etc. from QA & QC to the respective areas, e.g. Engineering workshop, scrap area etc.
2.0 SCOPE
This SOP is applicable for transferring all kinds of materials (e.g. remaining samples of raw & packaging ...
SOP for System Suitability Test for Chromatographic & Spectroscopic Analysis
1.0 OBJECTIVE
To provide a general guideline for the system suitability test for chromatographic (High Performance Liquid Chromatography & Gas Chromatography) & Spectroscopic (UV) analysis.
2.0 SCOPE
This SOP is applicable to tests like Assay, Related substances, Content Uniformity, Dissolution, ...
SOP for Operation Cleaning and Calibration of Refrigerator
1.0 OBJECTIVE
To set up a procedure for the operation, cleaning and calibration of Refrigerator.
2.0 SCOPE
This SOP is applicable for the operation, cleaning and calibration of Refrigerator-IV, ID.: QC/223 (Berjaya, Model No. XR30CX), of Quality Control Laboratory (F-2) of (Company Name).
3.0 RESPONSIBILITY ...
SOP for Operation Procedure of CITDAS
1.0 OBJECTIVE
To set up a procedure to operate the CITDAS software.
2.0 SCOPE
This procedure is applicable for operation of CITDAS software in Quality Control Department of (Company Name).
3.0 RESPONSIBILITY
3.1 QC Officer/Analyst shall be responsible to carry out the activity as per procedure.
3.2 ...
SOP for Operation of Ultrasonic Bath
1.0 OBJECTIVE
To set up a procedure for the operation and calibration of Digital Ultrasonic Bath.
2.0 SCOPE
This SOP is applicable for the operation and calibration of Digital Ultrasonic Bath, Model No. : Elmasonic S 50 R (Eq. ID: QC/229) in the Quality Control Department of (Company Name).
3.0 RESPONSIBILITY
3.1 ...
SOP for Operation of Shaking Water Bath
1.0 OBJECTIVE
To set up a guideline for the operation, cleaning and calibration of Shaking Water Bath.
2.0 SCOPE
This SOP is applicable for the operation, cleaning and calibration of Shaking Water Bath (Model No.: WSB45, Eq. ID.: QC/241).
3.0 RESPONSIBILITY
3.1 Operating personnel is responsible for ...
SOP for Operation of melting point apparatus
1.0 OBJECTIVE
To set up a procedure for the operation and cleaning procedure of Melting Point apparatus (Model: M-565)
2.0 SCOPE
This SOP is applicable for operation and cleaning procedure of Melting Point apparatus (Model: M-565, Eq. ID.: QC/248) at Quality Control Department (Company Name).
3.0 RESPONSIBILITY ...
SOP for Operation of Digital Torque tester
1.0 OBJECTIVE
To set up a procedure for operation, cleaning and calibration of Digital Torque Tester.
2.0 SCOPE
This SOP is applicable for the operation, cleaning and calibration of Digital Torque Tester at Quality control Department (Company name) of (Company name).
3.0 RESPONSIBILITY
3.1 Operating ...