1. Check and ensure that the area/ equipment/ are visually clean.
2. Check the area is free from previous product and unwanted materials
3. Ensure the temperature and relative humidity are within the specified limit as per mentioned in BMR.
4. Check the present status label which shows the details.
5. Check the proper gowning of personnel.
6. Ensure the availability of BPR and filled upto the stage
7. Check the wash water report of tank/ nozzles.
8. Check the filled volume of bottles(total no of nozzles)
9. Ensure the dust bin is clean and wrap with new poly bags.